Combi laminator with arched drying tunnel. Web path redrawn from the line's HMI overview screen; HMI values shown as field data in their original units.
Teal fields are the tensions read on the machine HMI: change them to test another setting or to enter values from another job. Dashed fields are assumptions. Everything below updates immediately.
K1 = 3.45 kPa and K2 = 120 are the best-fit values for a polyester film in a winding study (Oklahoma State University, presented at the 2013 Cambridge symposium), not values for a laminate. A stack-compression test on your laminate, before and after cure, would replace them with real data. Core stiffness and friction are assumptions.